2000 Series A-Base to Socket 2000 Series A-Base to Socket PDF

 

12 Standard Models Detailed Below.
Inquire about specials.
DEAD FRONT OPTION AVAILABLE

C/UL LISTED

  • Rated for Indoor or Outdoor Application.
  • Threaded inserts for “Banjo Box” meter base.
  • Grounding system standard on all models.
  • Tamper indicator on terminal cover, sealable retaining screw.
  • UL Listed, proprietary blend, fiberglass reinforced polycarbonate housing. All UL Listed Self-Contained units rated 125A Continuous – 150A Maximum
  • All UL Listed CT Rated units rated 30A Continuous 300V US – 240V Canada Rated Optionally rated for 200A Max service at 160A Continuous.

INDOOR AND OUTDOOR RATED

2000 Series A-Base enclosure
2000-3W-160-NR SHOWN
UL Listed logo

 

2000-2W-125A
2000-2W-125A wiring diagram
2000-2W-5J-125A
2000-2W-5J-125A wiring diagram
2000-2W-2WM-125A
2000-2W-2WM-125A wiring diagram
2000-3W-125Ad
2000-3W-125A wiring diagram
MODEL SERVICE METER TERMINALS JAWS
2000-2W-125A 2 WIRE 3 WIRE 4 4
NOTE: #16 AWG WIRE, POTENTIAL LINK TO TERMINAL BLOCK.
2000-2W-5J-125A 2 WIRE 3 WIRE 4 5
NOTE: #12 AWG WIRE, 5TH JAW TO NEUTRAL JUMPER.
2000-2W-2WM-125A 2 WIRE 2 WIRE 4 3
NOTE: #12 AWG WIRE, UPPER RIGHT JAW TO NEUTRAL JUMPER.
2000-3W-125A 3 WIRE 3 WIRE 4 4
  2 WIRE 2 WIRE 4 4

 

2000-3W-5J-125A
2000-3W-5J-125A wiring diagram
2000-3W-5J5T-125A
2000-3W-5J5T-125A wiring diagram
2000-3W-6J CT Rated
2000-3W-6J-CT-Rated wiring diagram
2000-3W-6J6T CT Rated
2000-3W-6J-CT-Rated wiring diagram
MODEL SERVICE METER TERMINALS JAWS
2000-3W-5J-125A 3 WIRE 3 WIRE 4 5
NOTE: #12 STRANDED WIRE, 5TH JAW THROUGH TERMINAL BLOCK.
2000-3W-5J5T-125A 3 WIRE 3 WIRE 5 5
NOTE: #12 SOLID COPPER WIRE, 5TH JAW TO 5TH TERMINAL IN TERMINAL BLOCK.
2000-3W-6J CT Rated 3 WIRE 3 WIRE 4 6
NOTE: #12 STRANDED WIRE, 5TH & 6TH JAW THROUGH TERMINAL BLOCK.
2000-3W-6J6T CT Rated 3 WIRE 3 WIRE 6 6
NOTE: #12 SOLID COPPER WIRE, 5TH & 6TH JAW TO TERMINALS IN TERMINAL BLOCK.

 

OPTIONS
-160 RATED FOR 200A SERVICE AT 160 AMP CONTINUOUS CURRENT RATING.
– LG LESS GROUND, OMIT SURGE GROUND STRAPS.
– DS DEEP STOPS, EXTRA DEEP WIRE STOPS, 5/8 INCH DEEPER THAN NORMAL.
2000-3S-2-3A CT Rated
2000-3S-2-3A-CT-Rated wiring diagram
2000-3S-2-3A-BP CT Rated
2000-3S-2-3A-BP-CT-Rated wiring diagram
2000-3W-2-6J-BP CT Rated
2000-3W-2-6J-BP-CT-Rated wiring diagram
MODEL SERVICE METER TERMINALS JAWS
2000-3S-2-3A CT Rated 2 WIRE 2 WIRE 4 5
NOTE: 3S TO 3A TRANSFORMER RATED.
2000-3S-2-3A-BP CT Rated 2 WIRE 2 WIRE 4 5
NOTE: 3S TO 3A TRANSFORMER RATED WITH AUTOMATIC CURRENT BYPASS.
2000-3W-2-6J-BP CT Rated 3 WIRE 3 WIRE 6 6
NOTE: 3W TO 6J TRANSFORMER RATED WITH AUTOMATIC CURRENT BYPASS.
2000-3W-2-6J6T-BP CT Rated 3 WIRE 3 WIRE 6 6
NOTE: 3W TO 6J TRANSFORMER RATED WITH AUTOMATIC CURRENT BYPASS.